消防應(ying)急(ji)燈(deng)可解決臨時停電問(wen)題(ti),因此在(zai)城鄉的許多家庭中都有應(ying)急(ji)燈(deng),以(yi)備(bei)停電時使用(yong)。當然,由于各(ge)種原因,應(ying)急(ji)燈(deng)在(zai)使用(yong)中不可避免地(di)會(hui)出現故(gu)障(zhang)(zhang)。本(ben)文以(yi)一款(kuan)11W國產應(ying)急(ji)燈(deng)為例,分析(xi)應(ying)急(ji)燈(deng)常見故(gu)障(zhang)(zhang)及維(wei)修(xiu)方(fang)法,僅供參考。
故障維修 :
1.接通開關SA1后應急燈不亮
斷開(kai)SA1,用(yong)萬(wan)(wan)用(yong)表直流(liu)1A檔(dang)(若無此檔(dang),也可用(yong)500mA檔(dang)速測)并在(zai)(zai)SA1兩(liang)端,正常(chang)(chang)時(shi)電(dian)流(liu)應(ying)在(zai)(zai)500-V 600mA左右。注意,此時(shi)開(kai)關(guan)(guan)SA2應(ying)在(zai)(zai)“點(dian)(dian)燃”位置。若電(dian)流(liu)正常(chang)(chang),說明SA1損壞(huai),需更換(huan):若無電(dian)流(liu),應(ying)重點(dian)(dian)檢(jian)查(cha)T2的(de)繞(rao)組L4, L5,可用(yong)萬(wan)(wan)用(yong)表歐姆檔(dang)測量判(pan)斷:{zh1}再焊(han)下(xia)VT測其性能(neng)是(shi)(shi)否(fou)良好,需更換(huan)時(shi)可用(yong)β值(zhi)在(zai)(zai)120以上(shang)的(de)中功(gong)率(lv)管。若仍無電(dian)流(liu),再用(yong)萬(wan)(wan)用(yong)表分別(bie)檢(jian)查(cha)電(dian)阻(zu)R2、 R3是(shi)(shi)否(fou)變值(zhi)或斷路,VD7. C2是(shi)(shi)否(fou)短(duan)路。經(jing)上(shang)述檢(jian)修處理后,接通開(kai)關(guan)(guan)SA1,燈(deng)管應(ying)能(neng)正常(chang)(chang)點(dian)(dian)亮。詳情還可以看看: 消防應(ying)急(ji)照明燈(deng)的(de)功(gong)能(neng)及相關(guan)(guan)常(chang)(chang)識(shi) !
2.市電供電正常但指示燈不亮
此故障多為發光(guang)二(er)極(ji)管損壞所致(zhi),可焊下VD5用萬用表(biao)判斷其是否完好。限流電阻(zu)R1阻(zu)值變大(da)或(huo)開路也會導致(zhi)VD5不亮。
3.市電停電時,指示燈仍亮
該(gai)故障是VD6反向(xiang)特性變差(cha)或擊(ji)穿所致。只要更換一只IN4004整流(liu)二極(ji)管,故障即(ji)可排除(chu).
4.停電后燈管正常工作片刻即亮度下降
這表明蓄電池可能有故障。由于該電路無防止蓄電池過放電的保護措施,若市電停電時間過長,蓄電池過放電至端電壓10V時,未能斷開SA1,將使蓄電池過放電而導致其極板過早損壞。
解決(jue)蓄(xu)電(dian)(dian)池(chi)(chi)(chi)過(guo)放電(dian)(dian)的辦法{zh0}是(shi)設置保護電(dian)(dian)路(lu),如圖2所示(shi)。該電(dian)(dian)路(lu)較簡單,在應急照(zhao)明過(guo)程中(zhong),當蓄(xu)電(dian)(dian)池(chi)(chi)(chi)放電(dian)(dian)至端(duan)電(dian)(dian)壓低于(yu)lOV時,VD截止,繼電(dian)(dian)器(qi)KA釋放,切斷蓄(xu)電(dian)(dian)池(chi)(chi)(chi)負載回(hui)路(lu),避(bi)免過(guo)放電(dian)(dian)而縮(suo)短其使用壽命。KA可選(xuan)用國產JRX-13F型高靈敏度繼電(dian)(dian)器(qi),其吸(xi)合(he)電(dian)(dian)流(liu)為8mA,吸(xi)合(he)電(dian)(dian)壓為6V。穩壓二極管(guan)穩壓值為5V.
5.燈管點燃電路故障
該應急(ji)燈(deng)電(dian)(dian)路中開關(guan)SA2的(de)(de)(de)作(zuo)用是:當SA1閉合,SA2置于“啟動”位置時,振蕩變壓器T2繞(rao)(rao)組(zu)L1上(shang)的(de)(de)(de)電(dian)(dian)壓通過SA2和電(dian)(dian)源地(蓄電(dian)(dian)池)加到燈(deng)管一(yi)端(duan)的(de)(de)(de)燈(deng)絲上(shang),而繞(rao)(rao)組(zu)L3上(shang)的(de)(de)(de)電(dian)(dian)壓加在(zai)燈(deng)管另一(yi)端(duan)的(de)(de)(de)燈(deng)絲上(shang),經過約三秒的(de)(de)(de)預熱后,開關(guan)SA2撥到“點燃”位置,此時,繞(rao)(rao)組(zu)L2上(shang)感應的(de)(de)(de)高頻脈沖電(dian)(dian)壓加在(zai)燈(deng)管兩端(duan),燈(deng)管被點亮。
根據上述工作原理,在(zai)檢(jian)修燈管(guan)點燃方面的(de)故障時,首先應(ying)檢(jian)查(cha)開(kai)關SA2的(de)接觸是否良好,然后再(zai)檢(jian)查(cha)燈管(guan)的(de)燈絲(si)是否完好,可(ke)用(yong)萬用(yong)表RX1檔測其阻(zu)值。由于該應(ying)急燈的(de)燈管(guan)燈絲(si)均有預(yu)熱且有電容C3改善電壓(ya)波形(xing),一般較少出現燈管(guan)一端發黑的(de)現象(xiang)。